This standard is issued under the fixed designation D ; the number 1 This test method is under the jurisdiction of ASTM Committee D on Plastics. ASTM D is similar to ISO and describes a procedure for determining the compressive properties of rigid cellular materials. Similar to ISO , ASTM D is a testing standard designed to measure the compressive properties of rigid cellular plastics (i.e. foam).

Author: Nirisar Kajigar
Country: Maldives
Language: English (Spanish)
Genre: Business
Published (Last): 16 October 2009
Pages: 457
PDF File Size: 18.4 Mb
ePub File Size: 4.33 Mb
ISBN: 422-7-93283-349-9
Downloads: 46669
Price: Free* [*Free Regsitration Required]
Uploader: Gardakora

ASTM D Compressive Properties Rigid Cellular Plastics – Instron

Swivel seating can be placed on the platen attached to axtm instrument’s base or load cell in the moving crosshead. Due to the very large number of tests offered, ast of those most commonly requested have been gathered into the following groups:.

Next Checking to see if you are a returning visitor…. Onsite Training At Your Facility. Test data is obtained, and from a complete load-deformation curve it is possible to compute the compressive stress at any load such as compressive stress at proportional-limit load or compressive strength at maximum load and to compute the effective modulus of elasticity.

The tests cannot be considered significant for engineering design in applications differing widely from the atsm – time scale of the standard test. The data obtained from the compression tests provide a standard method of obtaining data for research and development and quality control. Glossary of Materials Testing Terms.

ASTM D1621 – Compression Testing of Rigid Cellular Plastics

Please confirm that you agree with our privacy and cookies policy to submit this form. Touchstone Research Laboratory, Ltd. Software for Series Systems. Astj has a large environmental chamber photo on right capable of conditioning a wide range of sample sizes.

  GAROFOLI PORTE CATALOGO PDF

The x series LVDTs can mount directly on the series compression platens.

ASTM D1621-16 Compressive Properties of Rigid Cellular Plastics

The Plastics Testing Solutions brochure is a page, applications-focused, and standards-based brochure. Email addresses must contain the symbol.

If there are no material specifications, then the default conditions apply. Subscribe to Our Newsletters.

Description Literature Contact Us ASTM D specifies the test conditions for determining the compressive properties of rigid cellular materials, particularly expanded plastics. WaveMatrix 2 for Dynamic Testing.

After testing and analysis, compressive strength, modulus and deformation at maximum load are reported. Any test specimen preparation, conditioning, dimensions, or testing parameters, or a combination thereof, covered in the materials specification shall take precedence over those mentioned in this test method. The values in parentheses are for information only. The preload function in Bluehill Universal software automatically moves the upper compression platen down to precisely touch the specimen at a pre-defined load.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Such applications require additional tests such as impact, creep, and fatigue. By continuing to use our site, you accept our cookie policy. Select from list below: Suitable systems for this application include Series and Series electromechanical testing machines equipped with compression platens.

  1000 KIKUYU PROVERBS PDF

The brochure addresses the most prominent and widely-used standards in the materials testing industry for plastics. ASTM D specifies the test conditions for determining the compressive properties of rigid cellular materials, particularly expanded plastics.

ASTM D – 16 Standard Test Method for Compressive Properties of Rigid Cellular Plastics

Bluehill Universal Brochure Bluehill Universal Software is built from the ground-up for touch interaction and an intuitive user experience.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Specimen c1621 isplacement and load are recorded throughout the test.

Contact Us View Accessories Catalog. Discover simpler and smarter testing with features such as pre-loaded test methods, QuickTest in seconds, enhanced data exporting: The preload function reduces the amount of operator interaction, saving time and improving accuracy.

Bluehill LE for Basic Testing. Link to Active This link will always route to the current Active version of the standard. The self-aligning nature of this fixture will maximize the contact area between the platen and the specimen.

Email addresses wstm only contain letters, numbers and the following special characters: Bluehill Universal Software is built from the ground-up for touch interaction and an intuitive user experience. Concrete, Asphalt and Rock.